Portable Burn Pan: Difference between revisions

Jump to navigation Jump to search
m
Line 53: Line 53:
* 7.) Two to two and a half gallons of water to fill the base unit.
* 7.) Two to two and a half gallons of water to fill the base unit.
* 8.) A dry-chem extinguisher to have on hand for safety, '''''not''''' for demonstration use.
* 8.) A dry-chem extinguisher to have on hand for safety, '''''not''''' for demonstration use.
* 9.) A vehicle or two to haul all this, and to provide power to the base unit. Everything can fit in one SUV or ''maybe'' a hatchback, or two standard sized sedans
* 9.) A vehicle or two to haul all this, and to provide power to the base unit. Everything can fit in one SUV or ''maybe'' a hatchback, or two standard sized sedans.
* 10.) Sufficient prep time. You'll want 15 minutes for each extinguisher you need to prep, and 15 minutes to prep the base unit system.
<br/>
<br/>


=== System Set-up ===
=== System set-up ===


# Place the base unit in an open area away from all combustible materials. Ensure the front of the system is down wind (i.e. the wind is at the trainee's back).
# Place the base unit in an open area away from all combustible materials. Ensure the front of the system is down wind (i.e. the wind is at the trainee's back).
Line 68: Line 69:
# Attach the yellow power cable to the rear of the base unit.
# Attach the yellow power cable to the rear of the base unit.
# Fill the burn pan with water to the side overflow cut-outs (roughly two gallons).
# Fill the burn pan with water to the side overflow cut-outs (roughly two gallons).
<br/>
# Level the base unit using the adjustable feet.
# Remove the sensor guard.
# Confirm that a CO<small>2</small> or dry chem extinguisher is nearby and ready.
# Do a quick visual inspection for damage over the whole system.
 
=== System use ===
 
# Open the valve on the propane tank.
# Plug the male end of the yellow power cable into the 12V DC power receptacle.
# Enter the start sequence.
# Set difficulty level and class of fire to desired conditions.
# Push and hold the '''HOLD TO RUN''' button. The main burners will ignite.
# Trainees should be instructed to start fighting the fire when the timer on the LCD screen starts counting.
 
=== Setting the difficulty ===
 
# Release all buttons on the handheld controller.
# Press and hold down the round FLARE UP button.
# After 3 seconds, the difficulty set menu will be displayed on the LCD screen.
# While continuing to hold down the round FLARE UP button, use the selector knob to change the difficulty level. There are four difficulty levels: 1, 2, 3, and 4, with 4 being the most difficult. On the selector knob, '''A''' corresponds to level 1, '''B''' corresponds to level 2, etc.
# Release the round FLARE UP button to lock in the difficulty level. The difficulty level is displayed on the LCD screen.
 
=== Setting the class of fire ===
 
# The class of fire can be set by moving the selector knob to either '''A''', '''B''', '''C''', or '''Full'''.
# The class of fire chosen will be displayed next to the difficulty setting.<br />


=== SmartExtinguisher Information ===
=== SmartExtinguisher Information ===

Navigation menu